Skip Navigation

Europace 2005 7(3):290; doi:10.1016/j.eupc.2005.02.014
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Ismer, B.
Right arrow Articles by Nienaber, C.A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Ismer, B.
Right arrow Articles by Nienaber, C.A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2005 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.

CP16: UTILIZATION OF THE ICS3000 PROGRAMMER TO MEASURE INTERATRIAL CONDUCTION INTERVALS AND TO OPTIMIZE THE AV DELAY IN PATIENTS WITH BIVENTRICULAR PACE-MAKERS AND ICDs IRRESPECTIVE OF MAKE AND MODEL

B. Ismer, T. Körber, G.H. von Knorre, W. Voss, F. Weber, C. Melzer*, R. Peters** and C.A. Nienaber

Division of Cardiology, University Hospital Rostock and Charite Berlin, Germany; Divisions of Cardiology, University Hospital Rostock and Biotronik Berlin, Germany

The current Biotronik ICS3000 programmer software enables recording of a filtered esophageal left atrial electrogram (LAE) in addition to the surface ECG. It can be utilized to measure interatrial conduction intervals (IACT) in patients with DDD systems irrespective of make and model.

AIMS: To study relations between interatrial conduction intervals and optimal Doppler AV delay (AVD) in biventricular paced congestive heart failure (CHF) patients and to test ICS3000 for simplified AVD optimization.

METHODS: LAE and transmitral flow (TMF) were recorded simultaneously to measure determinants of the optimal AV delay (AVD) in 32 CHF patients (21 Medtronic, 11 Biotronik DDD or ICD systems: 20m, 12f, 65,3±10,4y, NYHA III, QRS150ms): Programming unphysiologically long AVD in VDD operation, 1. IACT was AVD minus interval between left atrial deflection (LA) and ventricular stimulus (Sv). 2. Duration of undisturbed left atrial electromechanical contribution (LA-EAClong) was measured between LA and end of atrial contribution (EAC) in TMF. During unpysiologically short AVD in DDD operation we measured 3. IACT between atrial stimulus and LA and 4. the latency of prematurely ending atrial contribution (Sv-EACshort) between Sv and EAC in TMF. In VDD and DDD operation, optimal AVD was calculated by the formula AVDoptimal = IACT + LA-EAClong - Sv-EACshort.

RESULTS: Results are demonstrated in the table as mean±SD:


View this table:
[in this window]
[in a new window]
 
 
CONCLUSIONS: 1.Optimal AVD in CHF patients was found to be on average 45ms longer than individual interatrial conduction interval. Thus, 2. irrespective of make and model, the ICS3000 programmer based LEA can be used to approximate the optimal AVD in biventricular pacing by adjusting about 45ms between left atrial deflection and ventricular stimulus.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.